[Features]
◆Control 2 and 4 door independently
◆Storage Capacity up to 20,000 cards and 20,000 transactions
◆Standalone Operation or Communicate with PC via RS-232, RS-485 or TCP/IP
◆Running on 16 bit CPU
◆Support ”Toggle Mode”, mainly use for controlling on/off of large-scale electrical equipment
◆Support Anti-passback
◆Support Anti-tailgating
◆Support Arm/Disarm function
◆Support Door interlock function
◆Connect maximum 8 wiegand readers or 485 readers simultaneously
◆Programmable Time zone / Pin Access Control
◆Support external serial port printer
◆Able to output alarm to 3rd party device via RS-485
◆Support any 3rd party external Wiegand Reader or Keypad Reader
◆Recoverable up to the latest 20,000 transaction if back end system failure
◆Control each door auto release function
◆Able to work with other BS series controller within the same network
◆CE Certified
[Functional List]
Function |
Description |
Card Open Door |
Present card to external wiegand or 485 reader |
Card+PIN Open Door |
Connect with BS32, BS36K and BS361K keypad reader via wiegand or RS-485 connector
Open door either by enter Security PIN or Card ID
Open Door by Card + Pin: 4 digits PIN; By Security PIN: 8 digits PIN |
Security PIN Open Door |
|
Card ID Open Door |
|
Fingerprint Open Door |
Connect to BS fingerprint reader via wiegand connector. Access Mode can be set to: Card + Fingerprint, ID + Fingerprint, Fingerprint + PIN, Card + Fingerprint + PIN, ID + Fingerprint + PIN, Card Only, Card + PIN, PIN only, ID only etc. |
Connect External
Wiegand Reader |
Support any 26/ 34 bit wiegand card reader and free wiegand card reader |
Free Wiegand Setting |
Yes. Able to configure card battery low-voltage alarm when using long range reader |
Connect External
Keypad Reader |
Wiegand keypad reader
BS range readers inclusive BS32, BS36K and BS361K keypad reader |
Connect External
BS Fingerprint Reader |
Yes, via wiegand port |
Connection to PC |
Via RS232, RS485 or TCP/IP (require TCP/IP converter) |
Exit by Push Button |
Yes |
Door Force Open Alarm |
Yes |
Door Held Open Alarm |
1-255 seconds. Factory default is 5 seconds. Alarm output can be disable |
Add/Delete Card
in standalone mode |
Yes |
Multi-card Verification |
Yes, up to 8 cards |
Keypad Open Door |
Through controller keypad. |
Wrong PIN Control |
By flow control. Able to setup PIN enter incorrectly to lockout controller
or reader |
Same Card Delay |
0-255 seconds. Factory default is 0 second. |
Time Zone Control |
32 set of time zone |
|
Yes |
Lost/Inhabit Card |
Yes |
Card Start and Expiry
Date Validation |
Yes |
Door Auto Unlock by
Timezone |
Yes |
Dynamic Storage Adjustment |
Yes |
Connect External Printer |
Yes |
Alarm and Event Output |
Via 3rd |
Anti-passback |
Yes (Local or Global). Able to reset manually or by time |
Anti Tailgating |
Yes |
Time Error Correction |
Yes |
Card Number Output Byte |
1-4 bytes. Default is 4 bytes |
Card Number Display Format |
HEX, DEC, |
Communication Monitoring |
Yes |
PIN Control |
Able to setup Exit without PIN Control. Factory default is Yes. |
Timezone Control |
Able to set to Exit without Timezone Control. Factory default is Yes. |
Tamper Alarm |
Build-in tamper switch. If device is opened, controller will send an alarm record to back end PC. |
Door Left Open Restore
transaction |
Yes |
485 Comm Terminating
Resistor |
Via jumper setting |
Auto Monitoring |
Yes (Auto DI) |
Auto Control |
Yes (Auto DO) |
485 Reader ID |
Able to modify 485 Reader ID via controller |
Reader & Controller Relation |
Able to modify |
Door Sensor Alarm Channel |
Able to modify |
Cancel TTL changes
follow door sensor |
Yes |
Door Interlock |
Able to setup 2 or more interlocking door |
[Technical Specification]
Parameter |
BS600-3 |
BS600-2 |
|
CPU |
16 bits, 8MHz |
||
RAM |
512K Bytes |
||
Flash |
256K Bytes |
||
Number of Door |
4 |
2 |
|
Wiegand Reader Connect |
8 |
4 |
|
485 Reader Connect |
8 |
4 |
|
TTL Alarm Input |
8 |
8 |
|
Door Sensor |
4 |
2 |
|
Exit Push button |
4 |
2 |
|
TTL Alarm Output |
8, 5V/300mA |
8, 5V/300mA |
|
Alarm Relay Output |
1, 12V/1A |
1, 12V/1A |
|
Door Relay Output |
4, 12V/1A |
2, 12V/1A |
|
Tamper Switch |
1 |
1 |
|
Card Capacity |
20,000 |
20,000 |
|
Record Capacity |
20,000 |
20,000 |
|
|
3, 1x485 connect to PC,1x485 connect to 485 reader, 1x232 connect to serail printer or PC |
||
Baud Rate |
1200~19200 bps. Default is 19200 bps |
||
Controller ID Setting |
001~255.Default is 1 |
||
Data Backup |
Rechargeable. Without main power able to save the data for 6 months |
||
Keypad |
3x4, Green Backlight |
||
LCD |
16x2 line,Blue Backlight, English Menu |
||
Buzzer |
1, audible sound able to distinguish valid and invalid card |
||
Power Supply |
9~30VDC, 300mA |
||
Operating Temperature |
-10~50℃ |
||
Dimension |
152 x 106 x 36 mm |
||
Casing |
ABS flame-resistant |
||
Mounting |
Wall mount |
[Model Selection]
Model |
Description |
BS600-XXX-2 |
2 door controller, RS485 comm to PC |
BS600-XXX-3 |
4 door controller, RS485 comm to PC |
[Installation Measurement]