[Features]
	◆ Single door controller, control IN/OUT of one door
◆ Max 10,000 Card Holders
◆ Max 10,000 lines Transaction
◆ Can be standalone or connect to PC via RS-232/RS-485 or TCP/IP
◆ Using 16-bit microcontrollers
◆ Separately configure door access mode by PIN or Time Zone Control
◆ Can connect to external printer
◆ Support any wiegand reader or keypad reader in the market
◆ Recoverable 10,000 lines of transaction should there be any system failure
◆ Support built-in EM, Mifare or HID125 KHZ proximity , HID 13.56 MHz iCLASS Card reader module
◆ CE Certified
	
[Functions]
| 
				 Functions  | 
			
				 BS36  | 
			
				 BS501  | 
		
| 
				 Card Open Door  | 
			
				 Connect wiegand reader  | 
		|
| 
				 Card + PIN Open Door  | 
			
				 
					1. Using Access Controller   | 
		|
| 
				 PIN Open Door  | 
		||
| 
				 Card ID Open Door  | 
		||
| 
				 Conect External Wiegand Reader  | 
			
				 Connect External 26/32 Wiegand Card Reader  | 
		|
| 
				 Free Wiegand Setup  | 
			
				 Yes. Can set low battery voltage alarm when use with long range card reader.  | 
		|
| 
				 Connect External Keypad Reader  | 
			
				 
					wiegand keypad reader   | 
		|
| 
				 Connect External BS Fingerprint Reader  | 
			
				 Yes  | 
		|
| 
				 Communication with PC  | 
			
				 RS-232/485 or TCP/IP ( require TCP/IP converter)  | 
		|
| 
				 Push Button Open Door  | 
			
				 Yes  | 
		|
| 
				 Door Force Open Alarm  | 
			
				 Yes  | 
		|
| 
				 Door Open Too Long Alarm  | 
			
				 Door open delay can be set from 1~255 seconds. Factory default is 5 seconds. Alarm can be disabled.  | 
		|
| 
				 Add & Delete Cards During Offline  | 
			
				 Yes  | 
		|
| 
				 Multi-cards Verification  | 
			
				 Max. 8 cards  | 
		|
| 
				 Key Press Open Door  | 
			
				 Using controller's keypad to open door. Factory default is set to false  | 
		|
| 
				 Invalid PIN Control  | 
			
				 When using Card + PIN open door and number of PIN > 3, controller will be disabled for 30 seconds.  | 
		|
| 
				 Same Card Delay Control  | 
			
				 0~255 seconds. Factory default is 0  | 
		|
| 
				 Time Zone Control  | 
			
				 32 groups of time zone  | 
		|
| 
				 Holiday Control  | 
			
				 Yes  | 
		|
| 
				 Report Loss Card  | 
			
				 Yes  | 
		|
| 
				 Card Validity Control  | 
			
				 Yes  | 
		|
| 
				 Door Auto Release Time Zone  | 
			
				 Yes  | 
		|
| 
				 Connect External Printer  | 
			
				 Yes  | 
		|
| 
				 Anti-passback  | 
			
				 Yes, can be reset  | 
		|
| 
				 Timeout Events  | 
			
				 Yes  | 
		|
| 
				 Arm & Disarm Alarm  | 
			
				 Yes  | 
		|
| 
				 Anti-tailgating  | 
			
				 Yes  | 
		|
| 
				 Time Correction  | 
			
				 Yes  | 
		|
| 
				 Card No. Output Byte  | 
			
				 1~4. Default is 4  | 
		|
| 
				 Card No. Display Format  | 
			
				 HEX,DEC,ABA,USER CODE. Default is DEC  | 
		|
| 
				 Communication Monitoring  | 
			
				 Yes  | 
		|
| 
				 In-built Buzzer Alarm  | 
			
				 When door open too long or being forced open, can be set to turn on the alram. Factory default is set to false.  | 
		|
| 
				 PIN Control  | 
			
				 Can be set to 'No PIN Control'. Default is yes.  | 
		|
| 
				 Time Zone Control  | 
			
				 Can be set to 'No Time Zone Control' Default is yes.  | 
		|
| 
				 Tamper Alarm  | 
			
				 Built-in Tamper switch. Trigger alarm event to PC when device is force open.  | 
		|
| 
				 Reset Door Open Too Long  | 
			
				 Yes  | 
		|
| 
				 Terminal Resistance  | 
			
				 Setup using jumper  | 
		|
	
	
[Techinical Specification]
	
| 
				 Parameters  | 
			
				 BS36  | 
			
				 BS501  | 
		
| 
				 CPU  | 
			
				 16 bits  | 
		|
| 
				 Control No. of Doors  | 
			
				 1  | 
		|
| 
				 Connect Wiegand Reader  | 
			
				 2  | 
		|
| 
				 TTL Alarm Input  | 
			
				 1  | 
		|
| 
				 Door Sensor Signal  | 
			
				 1  | 
		|
| 
				 Push Button Signal  | 
			
				 1  | 
		|
| 
				 TTL Alarm Output  | 
			
				 1, 5V/300mA  | 
		|
| 
				 Alarm Relay  | 
			
				 1,12V/1A  | 
			
				 1, 12V/1A  | 
		
| 
				 Door Relay  | 
			
				 1, 12V/1A  | 
			
				 1, 12V/1A  | 
		
| 
				 Tamper Switch  | 
			
				 1  | 
		|
| 
				 Card Capacity  | 
			
				 10,000  | 
		|
| 
				 Transaction Capacity  | 
			
				 10,000  | 
		|
| 
				 COM Port  | 
			
				 2, one is using RS-485 to communicate with PC, another one using RS-232 to communicate with printer or other PC. (3rd port can be set as RS-485 port).  | 
		|
| 
				 Baud Rate  | 
			
				 1200-19200bps, Default is 19200bps  | 
		|
| 
				 Device ID Setup  | 
			
				 001-254 , Default is 1  | 
		|
| 
				 Rechargeable Battery  | 
			
				 Data store up to 6 months without power  | 
		|
| 
				 Keypad  | 
			
				 4x4, blue backlight  | 
			
				 4x4, blue backlight  | 
		
| 
				 LCD  | 
			
				 128x64 dots, white backlight, chinese & english menu  | 
			
				 128x64 dots, white backlight, chinese & english menu  | 
		
| 
				 Buzzer  | 
			
				 1 with valid and invalid indicator  | 
		|
| 
				 Power Supply  | 
			
				 9-30VDC,300mA  | 
		|
| 
				 Operation Temperature  | 
			
				 -10~50 °C  | 
		|
| 
				 Dimension  | 
			
				 132×83×32mm  | 
			
				 161×112×36mm  | 
		
| 
				 Housing  | 
			
				 ABS flame-resistant  | 
		|
	
	
[Choosing A Model]
	
| 
				 Model No.  | 
			
				 Description  | 
		
| 
				 BS501  | 
			
				 Chinese Series Controller  | 
		
| 
				 BS501E  | 
			
				 Controller with EM Reader. Reading Distance >10cm  | 
		
| 
				 BS501M  | 
			
				 Controller with Mifare Reader. Reading Distance: >2.5cm  | 
		
| 
				 BS501H  | 
			
				 Controller with HID125 KHZ proximity Reader. Reading Distance: >4cm  | 
		
[Installation Measurement]
	