Function |
Description |
Card Open Door |
Connect wiegand reader or RS-485 reader |
Card + PIN Open Door |
1. Connect external BS36K-UM universal reader via RS-485 onnector |
PIN Open Door |
|
Card ID Open Door |
|
Fingerprint Open Door |
Connect BS fingerprint card reader via wiegand. At the same time the following mode can be implemented: Card + Fingerprint, ID + Fingerprint, Fingerprint + PIN, Card + Fingerprint + PIN, ID + Fingerprint + PIN, Card Only, Card + PIN, PIN Only , Card ID Only etc. |
Super User Card Open Door |
In case of emergency or system failure, make use of super user card to open door. (used with universal reader) |
Connect External 26/32 Wiegand Card Reader |
Yes |
Free Wiegand Setup |
Yes. Can set low battery voltage alarm when use with long range card reader. |
Connect External Keypad Reader |
1. Wiegand keypad reader via wiegand connector |
Connect External BS Fingerprint Reader |
Via Wiegand |
Communicate with PC |
1. Via RS-232/485 or TCP/IP. Use dial-up switch to set RS-232 or RS-485 2. Setup controller Device ID 001 - 255 via keypad 3. Setup IP address, Subnet Mask and Gateway via keypad |
Door Force Open Alarm |
Yes |
Door Open Too Long Alarm |
Door open delay can be set from 1~255 seconds. Factory default is 5 seconds. Alarm can be disabled. |
Add & Delete Cards During Offline |
Yes |
Dual cards Verification |
Yes |
Invalid PIN Control |
When using Card + PIN open door and number of PIN retry is over preset limits, the door will be remain locked until locking period is over then it is able to use. |
Same Card Delay Control |
0~255 seconds. Factory default is 0 |
Time Zone Control |
32 groups of time zone |
Holiday Control |
Yes |
Report Loss Card |
Yes |
Card Validity Control |
Yes |
Door Auto Release Time Zone |
Yes |
Anti-passback |
Yes. Can be reset and manage |
Card No. Output Byte |
1~4. Default is 4 |
Card Display Format |
HEX,DEC,ABA,USER CODE. Default is DEC |
Communication Monitoring |
Yes |
PIN and Time zone Control |
Can be setup to use either PIN control or time zone control |
Tamper Alarm |
Yes |
Reset Door Open Too Long |
Yes |
Terminal Resistance |
Via Dial-up switch to determine whether or not to terminate resistance |
RS-485 Reader ID Setup |
Can be set via controller |
Door Interlocking |
Can be set on 2 doors or more doors |
Power Monitoring |
Main power supply failure alarm and backup battery low voltage alarm |
Sensor Setup |
Door sensor normal behavior; sensitivity control; whether transaction based on door sensor action. |
Connect External Battery |
Yes |
[Technical Specification]
Parameter |
BS610-3 |
BS610-2 |
|
CPU |
ARM9, processor speed up till 200MHz |
||
Operating System |
Linux |
||
Control Door Area |
4 |
2 |
|
Connect Wiegand Reader |
4 |
4 |
|
Connect RS-485 Reader |
8 |
4 |
|
Door Sensor Signal |
4 |
2 |
|
Push Button Signal |
4 |
2 |
|
TTL Alarm Input |
4 |
4 |
|
Door Relay |
4, 12V/10A |
2, 12V/10A |
|
Alarm Relay |
4, 12V/10A |
4, 12V/10A |
|
TTL Alarm Output |
8,5V/300mA |
8, 5V/300mA |
|
Tamper Switch |
1 |
1 |
|
Card Capacity |
100,000 |
||
Card Matching Speed |
matching time <0.5second |
||
Transaction Capacity |
100,000 |
||
COM Port |
1. 2 ports |
||
TCP/IP |
1, communicate with PC at 10M/100M |
||
USB |
2, Master USB |
||
IIC |
1 |
||
SD Card |
1 |
||
JTAG |
1 |
||
Operation Keypad |
128x64 dots LCD, 4x4 keypad |
||
Buzzer |
Yes |
||
Clock Power Battery |
CR2032,3V |
||
Supply Voltage |
9-30V/400mA |
||
Operation Temperature |
-10~50 °C |
||
Dimension |
190 X 129 X 63mm |
||
Casing |
ABS flame-resistant |